Class B Fully Automatic Sterilizer
GDP Supreme Autoclave With Inbuilt Printer 23 L is a Premium Series Class B front-loading sterilization unit designed to meet the highest standards in infection control. With advanced vacuum technology and full Class B compliance, it ensures reliable sterilization of all instrument types - including solid, hollow, porous, wrapped, or unwrapped items.
Built with medical precision and high-performance features, it offers versatile operation with selectable programs at 121°C and 134°C. A large digital interface, intelligent cycle control, and an inbuilt printer make this unit an essential choice for modern clinics.
Passes all required international Class B sterilization protocols and tests (Helix Test Biological Indicators, Class 5 & Class 6 Chemical Indicators, Bowie-Dick Test). The GDP Supreme Autoclave delivers reliability, speed, and safety making it a perfect fit for practices that demand precision and compliance in every sterilization cycle.
Inbuilt Thermal Printer
Automatically prints complete cycle data including:
-
Date & time
-
Selected cycle & cycle count
-
Temperature & pressure
-
Total duration & operation sequence
-
Customizable clinic name
Provides documentation for compliance and record-keeping.
Fully Automatic Class B
Front Load & Large Tray Sizes
Dibya Industries 13 Shrestha Vihar Vikas Marg Ext Delhi delhi 110092 India
- Width: 470mm
- Height: 400mm
- Depth: 585mm
- Capacity: 23Ltr
- Power Consumption: 2KW
- Gross Weight: 35kg
- Inter Chamber Size: 260x450mm
- Tray: 3 Number of trays
- Dimension of Tray: 215x405mm
- Tray Material: Stainless Steel
Sterilization instrument:
- Sterilization Time: 16 Mins wrapped solid instruments.
Fast procedure:
- Sterilization Time: 6 Mins Wrapped instruments, surgical kits, phaco tubes and so on.
Quick Cycle:
- Sterilization Time: 5 Mins Rubber, fabric, wrapped hollow instruments, and so on.
Prion Cycle:
- Sterilization Time: 18 Mins Hollow instruments which contain a bloodthirsty virus, solid instruments, and so on.
Solid custom:
- Sterilization Time: 16 Mins Rubber, fabric, wrapped hollow instruments, and so on.
Vacuum test:
- Holding Time: 5 Mins Sterilizer sealing test.
Preparation: Ensure the autoclave is properly set up and connected to a power source.Check that the autoclave is clean and ready for use.
Loading Instruments: Place the instruments to be sterilized inside the autoclave, ensuring they are arranged properly for effective sterilization.
Setting Programs: Use the front control panel with touch-type key switches to select the appropriate program based on the type of instruments and sterilization requirements.Choose from multiple selectable programs at 134°C and 121°C as needed.
Starting the Cycle: Close the autoclave door securely. Initiate the sterilization cycle by pressing the start button.The autoclave will automatically perform pre-vacuum cycles, heating, sterilization, steam release, post-vacuum cycles, dry cycles, and more.
Monitoring: Monitor the digital display showing cycle parameters like temperature, pressure, and cycle time throughout the process.
Completion: Once the cycle is complete, wait for any necessary cooling or drying processes to finish.Open the autoclave door carefully after ensuring it is safe to do so.
Record Keeping: Utilize the inbuilt printer to print detailed cycle data after each cycle for record-keeping purposes.Ensure all necessary information like date, time, cycle details, and temperature are recorded for documentation.
Maintenance: After use, clean the autoclave as per manufacturer instructions to maintain its efficiency and longevity. Regularly check and maintain components like seals and gaskets for optimal performance.
Multiple Selectable Programs: Offers programs at 134°C and 121°C to meet various sterilization requirements.
Digital Display: Features a 4” large digital display showing detailed cycle parameters like temperature, pressure, and cycle time for monitoring.
Vacuum Cycles: Includes a total of 6 vacuum cycles, comprising 3 pre-sterilization, 1 post-sterilization, and 2 dry cycles.
Versatile Instrument Compatibility: Can sterilize wrapped/unwrapped, porous/non-porous, hollow, solid instruments, and even cotton swabs.
Control System: Equipped with ARM microprocessor control for precise operation.
Thermal Insulation: Special thermal wool and cloth insulation for efficient sterilization processes.
Pressure Sensor: Utilizes an imported Motorola pressure sensor for accurate control.
Inbuilt Printer: Prints detailed cycle data such as cycle time, cycle count, selected cycle, total time, and sequence of operation.
Vacuum Pump: Features an inbuilt two-headed high vacuum pump for post and pre-vacuum cycles.
Error Codes & Safety Features: Includes 13 error codes for diagnostics and automatic alarms in case of malfunctions, along with a silicon gasket to prevent air leakage.
Specialized Cycle: Offers a B+ cycle tailored for implantologists.
Large Tray Size: Accommodates any size of implant kit with its large stainless steel tray size.