Endodontic Files
-
-
-
-
-
-
-
- GDC Needle Holder Crile-wood TC Tip (15cm) (NHCWTC)Regular Price ₹3600 Special Price ₹2438
- GDC Needle Holder Derf TC Tip (12.5cm) (NHDTC)Regular Price ₹3600 Special Price ₹2438
- GDC Periosteal Elevator Freer (4mm/4mm) - 6 (884)Regular Price ₹2520 Special Price ₹1570
-
-
-
-
-
-
-
-
- GDC Root Elevators Root Tip Pick Set of 3 (EHBS3)Regular Price ₹2478 Special Price ₹1540
-
-
- GDC Scissors Crown & Band TC - Curved (12cm) (S5039)Regular Price ₹3300 Special Price ₹2052
-
- GDC Scissors Spencer For Suture Cutting (10cm) Angular TC (S13ATCS)Regular Price ₹3450 Special Price ₹2337
- GDC Scissors Spencer For Suture Cutting (13cm) Angular TC (S13ATCL)Regular Price ₹3450 Special Price ₹2337
-
-
- GDC Titanium Coated Composite Posterior Hollenbeck - 3 TNPLGH3 (TNPLGH3)Regular Price ₹1700 Special Price ₹1134
- GDC Titanium Coated Blue Composite Posterior Medium / Large Contact (TNCFIM/L)Regular Price ₹1700 Special Price ₹1134
- GDC Titanium Coated Composite Posterior Small/Medium Contact (TNPLGOT)Regular Price ₹1700 Special Price ₹1134
- GDC Titanium Coated Composite Posterior Tanner - OT TNCFIS/M (TNCFIS/M)Regular Price ₹1700 Special Price ₹1134
-
-
- GDC Perlogram CondenserRegular Price ₹274 Special Price ₹202Ergonomic DesignCorrosion Resistant
- GDC Gracey Curettes #6 (SG15/16)Regular Price ₹1800 Special Price ₹1124Ergonomic DesignCorrosion Resistant
- GDC Gracey Curettes #6 (SG13/14)Regular Price ₹1800 Special Price ₹1124AutoclavableCorrosion Resistant
Buy Endodontics Files Online In India
ENDODONTIC FILES:
Endodontic files are used in endodontic therapy to clean and shape the root canal. Complete chemomechanical preparation and debridement of the root canal up to the apical constriction is essential to ensure a higher prognosis of treatment. Typically, endodontic files are made from metal blanks which are twisted or machined to form various tapers and sizes.
What are the types of Endodontic Files?
Endodontic files can be grouped under two major heads based on their mode of use as, hand-operated or rotary files. The hand-operated or manual endodontic files are used with filing, reaming, rasping or pulling motions to remove the root canal dentin. Rotary endodontic files are used with handpieces powered by endomotors to automate the process of canal preparation.
Endodontic Hand Files:
Endodontic hand files are manually operated instruments used in biomechanical preparation of the root canal. Although before 1958 hand files were manufactured according to the manufacturers’ whim, standardization in the length, taper, cutting blades and other aspects were proposed by Ingle and Levine. Initially hand files were made of carbon steel. But stainless steel and nickel titanium were used as the material used for manufacture of endodontic files as they were more flexible and had lesser chances of fracture. Endodontic hand files are placed under Group 1 under the general classification of endodontic instruments.
K Files:
K files were first produced by the Kerr Manufacturing Company.
K file fabrication begins by cutting a round SS wire to form a tapered instrument having a square cross-section and pointed tips. The wire is now twisted in a counter clockwise direction to form flutes. The number of flutes can range from 1.5-2.5 per millimeter. K files are used in filing and reaming actions.
When a K file is locked inside the root canals –
- Clockwise rotation leads to unwinding and ductile fracture
- Counter clockwise rotation leads to brittle fracture
Some modifications of K files include K-Flex files and Flex-R files
H Files:
H files or Hedstrom files are fabricated by machine grinding a round stainless steel wire into a series of intersecting cones. The base of these cones have sharp edges ad function as cutting edges of the file. Due to this design H files cut root dentin only during the pulling stroke. The cross section of a H file can be seen as a “tear drop” with one cutting edge.
Care should be taken to not use H files in reaming motion because, the instrument design renders the shaft of the instrument at the junction of two cones weak, facilitating breakage. Hence H files are to be used in filing motion only.
Modifications of H files such as Safety Hedstroem files, Hyflex files, Unifiles and S files have been designed and manufactured.
Endodontic Rotary Files:
A Nickel Titanium (NiTi) rotary file is an engine-driven, pointed and tapered endodontic instrument made of Nickel Titanium alloy with cutting edges used to mechanically prepare and shape the root canals during endodontic therapy or to remove the root canal obturating material while performing retreatment. Rotary shaping instruments are replacing the conventional hand file systems to enhance the shaping ability of the canal, reducing clinical mishaps like blocks, ledges, transportation, and perforation. When the Dentists mastered the method of the using the products for rotary shaping instruments they could see unpredictable file breakage , metal fatigue, variation in length, loss of cutting efficiency, diameter and curvature of the canal can be avoided and better shaping of the canals with deserved taper will be achieved. Rotary endodontic practices have gained immense popularity among dental practitioners as they have many advantages over traditional manual instrumentation methods. The introduction of rotary files to the field of endodontics came two decades ago and the research and advancements are never-ending. Nickel Titanium has been the material of choice in manufacturing rotary files due to their superior properties.
Why Nickel Titanium?
- Elastic flexibility – 500% more stainless steel
- Higher capacity to withstand stress – 1000% more than stainless steel
- Greater resistance to torsional fractures
- Fewer cases of broken instruments, perforations and ledges
- Faster instrumentation of canals
- Superelastic property
- Corrosion resistant
A comparison of the features of a few commonly used rotary files have been tabulated below:
Features
Protaper
K3
Hyflex
Twisted Files
Revo-S
Manufacturer
Dentsply Mailefer
Sybron Endo
Coltene Whaledent
Sybron Endo
Micro Mega
Tip Sizes
#17 - #50
#15 - #60
#8 - #80
#25 - #50
#25 - #40
Taper
Progressively variable taper
2% - 10%
4% - 8%
4% - 12%
6% and 4%
Tip Types
Modified guiding tip
Safe cutting
Non-cutting
Non-cutting
Inactive
Cross section
Triangular
Asymmetric
Symmetrical
Triangular
Asymmetrical
No. of Radial Lands
Absent
3
Absent
Absent
Absent
Rake angle
+ve
+ve
-ve
+ve
Lengths (mm)
19, 21 & 25
21, 25 & 30
21 & 25
23 & 27
21, 25 & 29
Helical Angle
Variable
Variable
Constant
Variable
Constant
Speed Range (rpm)
150 – 350
300 - 350
500
500
250 – 400
Manual Variants
Available
Not available
Not available
Not available
Available
Technique
Coronal followed by apical sequential
Crown down
Crown down and apical enlargement
Crown down
Crown down
Things to keep in mind while using rotary files:
- Adequate access to the canals is crucial when using NiTi rotary files in biomechanical preparation
- Do no force rotary files as they are to be used with a passive technique
- Canals with difficult anatomy should be instrumented with hand files prior to rotary instrumentation
- Over using files results in decreased efficiency and increases risk of breakage
- Do not use the entire length of the file for cutting as it has a higher potential for fracture
- Accurate working length determination and adherence is of paramount importance in rotary endodontics
- Mastering rotary endodontics and avoiding breakage takes time
What are the advantages of rotary files over manual files?
Dentists tend to prefer rotary endodontics over the traditional manual methods of canal preparation for the following reasons:
- NiTi rotary files have a smoother and consistent cleaning effect on the root canal
- Rotary endodontic files are more reliable reducing the possibility of complications
- Treatment time is greatly reduced
- Rotary files are much quieter than manual files
- Increases patient comfort as treatment time is less and the procedure quieter.
What are the brands selling endodontic files online?
Coltene Whaledent, Dentsply, DiaDent, Eltee, FKG, Mani, Micro Mega, NeoEndo, Sybron Endo, EndoStar are some of the many brands selling endodontic files online at PinkBue.in
Why buy endodontic files from PinkBlue.in?
At PinkBlue.in we understand the importance quality dental tools for every dentist to aid them in delivery of quality dental treatment. To ensure the supply of standard dental products, all the items supplied are procured from trusted manufacturers and vendors. Products form indigenous and international brands are available for comparison and analysis before making a purchase. The assurance of quick delivery of orders along with the best prices for dental products makes PinkBlue.in the most efficient dental material supply chain in India.
What are the types of Endodontic Files?
Endodontic files can be grouped under two major heads based on their mode of use as, hand-operated or rotary files. The hand-operated or manual endodontic files are used with filing, reaming, rasping or pulling motions to remove the root canal dentin. Rotary endodontic files are used with handpieces powered by endomotors to automate the process of canal preparation.
Endodontic Hand Files:
Endodontic hand files are manually operated instruments used in biomechanical preparation of the root canal. Although before 1958 hand files were manufactured according to the manufacturers’ whim, standardization in the length, taper, cutting blades and other aspects were proposed by Ingle and Levine. Initially hand files were made of carbon steel. But stainless steel and nickel titanium were used as the material used for manufacture of endodontic files as they were more flexible and had lesser chances of fracture. Endodontic hand files are placed under Group 1 under the general classification of endodontic instruments.
K Files:
K files were first produced by the Kerr Manufacturing Company.
K file fabrication begins by cutting a round SS wire to form a tapered instrument having a square cross-section and pointed tips. The wire is now twisted in a counter clockwise direction to form flutes. The number of flutes can range from 1.5-2.5 per millimeter. K files are used in filing and reaming actions.
When a K file is locked inside the root canals –
- Clockwise rotation leads to unwinding and ductile fracture
- Counter clockwise rotation leads to brittle fracture
Some modifications of K files include K-Flex files and Flex-R files
H Files:
H files or Hedstrom files are fabricated by machine grinding a round stainless steel wire into a series of intersecting cones. The base of these cones have sharp edges ad function as cutting edges of the file. Due to this design H files cut root dentin only during the pulling stroke. The cross section of a H file can be seen as a “tear drop” with one cutting edge.
Care should be taken to not use H files in reaming motion because, the instrument design renders the shaft of the instrument at the junction of two cones weak, facilitating breakage. Hence H files are to be used in filing motion only.
Modifications of H files such as Safety Hedstroem files, Hyflex files, Unifiles and S files have been designed and manufactured.
Endodontic Rotary Files:
A Nickel Titanium (NiTi) rotary file is an engine-driven, pointed and tapered endodontic instrument made of Nickel Titanium alloy with cutting edges used to mechanically prepare and shape the root canals during endodontic therapy or to remove the root canal obturating material while performing retreatment. Rotary shaping instruments are replacing the conventional hand file systems to enhance the shaping ability of the canal, reducing clinical mishaps like blocks, ledges, transportation, and perforation. When the Dentists mastered the method of the using the products for rotary shaping instruments they could see unpredictable file breakage , metal fatigue, variation in length, loss of cutting efficiency, diameter and curvature of the canal can be avoided and better shaping of the canals with deserved taper will be achieved. Rotary endodontic practices have gained immense popularity among dental practitioners as they have many advantages over traditional manual instrumentation methods. The introduction of rotary files to the field of endodontics came two decades ago and the research and advancements are never-ending. Nickel Titanium has been the material of choice in manufacturing rotary files due to their superior properties.
Why Nickel Titanium?
- Elastic flexibility – 500% more stainless steel
- Higher capacity to withstand stress – 1000% more than stainless steel
- Greater resistance to torsional fractures
- Fewer cases of broken instruments, perforations and ledges
- Faster instrumentation of canals
- Superelastic property
- Corrosion resistant
A comparison of the features of a few commonly used rotary files have been tabulated below:
Features |
Protaper |
K3 |
Hyflex |
Twisted Files |
Revo-S |
Manufacturer |
Dentsply Mailefer |
Sybron Endo |
Coltene Whaledent |
Sybron Endo |
Micro Mega |
Tip Sizes |
#17 - #50 |
#15 - #60 |
#8 - #80 |
#25 - #50 |
#25 - #40 |
Taper |
Progressively variable taper |
2% - 10% |
4% - 8% |
4% - 12% |
6% and 4% |
Tip Types |
Modified guiding tip |
Safe cutting |
Non-cutting |
Non-cutting |
Inactive |
Cross section |
Triangular |
Asymmetric |
Symmetrical |
Triangular |
Asymmetrical |
No. of Radial Lands |
Absent |
3 |
Absent |
Absent |
Absent |
Rake angle |
+ve |
+ve |
-ve |
+ve |
|
Lengths (mm) |
19, 21 & 25 |
21, 25 & 30 |
21 & 25 |
23 & 27 |
21, 25 & 29 |
Helical Angle |
Variable |
Variable |
Constant |
Variable |
Constant |
Speed Range (rpm) |
150 – 350 |
300 - 350 |
500 |
500 |
250 – 400 |
Manual Variants |
Available |
Not available |
Not available |
Not available |
Available |
Technique |
Coronal followed by apical sequential |
Crown down |
Crown down and apical enlargement |
Crown down |
Crown down |
Things to keep in mind while using rotary files:
- Adequate access to the canals is crucial when using NiTi rotary files in biomechanical preparation
- Do no force rotary files as they are to be used with a passive technique
- Canals with difficult anatomy should be instrumented with hand files prior to rotary instrumentation
- Over using files results in decreased efficiency and increases risk of breakage
- Do not use the entire length of the file for cutting as it has a higher potential for fracture
- Accurate working length determination and adherence is of paramount importance in rotary endodontics
- Mastering rotary endodontics and avoiding breakage takes time
What are the advantages of rotary files over manual files?
Dentists tend to prefer rotary endodontics over the traditional manual methods of canal preparation for the following reasons:
- NiTi rotary files have a smoother and consistent cleaning effect on the root canal
- Rotary endodontic files are more reliable reducing the possibility of complications
- Treatment time is greatly reduced
- Rotary files are much quieter than manual files
- Increases patient comfort as treatment time is less and the procedure quieter.
What are the brands selling endodontic files online?
Coltene Whaledent, Dentsply, DiaDent, Eltee, FKG, Mani, Micro Mega, NeoEndo, Sybron Endo, EndoStar are some of the many brands selling endodontic files online at PinkBue.in
Why buy endodontic files from PinkBlue.in?
At PinkBlue.in we understand the importance quality dental tools for every dentist to aid them in delivery of quality dental treatment. To ensure the supply of standard dental products, all the items supplied are procured from trusted manufacturers and vendors. Products form indigenous and international brands are available for comparison and analysis before making a purchase. The assurance of quick delivery of orders along with the best prices for dental products makes PinkBlue.in the most efficient dental material supply chain in India.