Handheld X Rays. Lower Cost. But At What Cost?

Handheld X-Rays have been an appealing solution to many offices who like the idea of avoiding the cost of purchasing an X-ray for every operatory. However, before deciding if this solution is right for your office, it’s critical to know the entire picture. While the cost savings of not buying an X-ray unit for each operatory is attractive, there are six hidden pitfalls about handheld X-ray units that could have an impact on your practice.

1.Inconsistency

It’s harder to take consistently good X-rays with a handheld unit. The reason for this is that handheld X-ray units emit X-rays at a lower power than a high-quality wall mounted or mobile X-ray unit. The important factor to examine with a handheld is the amperage, or current output, which is designated in mA (or milliamps). Many of the handheld X-ray units have an output as low as 2 mA or 2.5 mA, while a wall mounted or floor mounted (mobile) X-ray is typically about 8 mA. The X-ray power is proportional to the mA. So, if all other parameters are similar, a 2 mA handheld generates an X-ray with about one quarter of the power of an 8 mA X-ray unit. When output power is lower, it is harder for the sensor or film to separate the signal from the noise, and this can result in lower image quality. With a handheld, a typical approach to compensate for this lower power is to increase the time of the exposure. However, with longer exposures come additional challenges in keeping both the patient and the X-ray still. Maintaining this stability for the duration can be challenging for some dental clinics.

2. Battery Charge

Forgetting to charge the handheld X-ray unit may disrupt your office. Most of the handheld units operate on a lithium-ion battery pack, and many cannot be operated without a charged battery. Usually, these battery packs last about 100 – 200 images. The challenge that many busy offices have is that if it’s not someone’s job to charge the battery pack when it’s needed, it may not get done. Eventually, this means that at some point, there is a good chance that your staff will grab the handheld with a patient in the chair, and it will be dead. Having a back-up battery pack may seem like a fail-proof solution. However, if that back up wasn’t placed on the charger, or if the back up wasn’t used for an extended period of time, then the back up may also be dead.

3. Weight Of The Unit

The dentist or hygienist has to carry the handheld during the radiological examination. Most of the handheld units weigh about 5 lbs, which is about the same as a large bag of flour. Over time, this additional fatigue can weigh on the staff. Also, because the operator no longer has free hands, the unit must be put down to make adjustments to the patient, which can further reduce productivity. In addition, because the entire weight of the unit must be held up and supported by the operator, aiming the unit freehand becomes more challenging. Also, remember that because of the low power level, more precise technique is required to get a good image. Yet, it’s harder to achieve good technique because it’s a heavy item that must be operated “freehand”.

4. Longer Duty Cycle

There will be a longer wait between exposures, so studies may take longer. The duty cycle (sometimes called the “duty factor”) tells you how long any X-ray needs to wait before it’s ready for the next shot. It represents the ratio of the exposure time to the wait time. Some wall mounted and mobile X-rays have a duty cycle that is a ratio of 1 to 15 (usually represented in a spec sheet as 1:15). This means that if the exposure lasts one quarter of a second, then the X-ray will be ready in less than 4 seconds (15 x 0.25 = 3.75). Many handheld units have a duty cycle of 1 to 60 (1:60) or worse. Therefore, that same quarter second exposure now means the operator has to wait 15 seconds until the next exposure. However, remember that a common way to compensate for the lower power is to increase the exposure time. Therefore, this wait time can be even longer if the exposure time is increased. If you increase the exposure to 0.5 seconds, now the operator has to wait a half minute between exposures. If you apply this to an adult FMX study, this can equate to almost 10 minutes of extra time per patient. Also, as mentioned above, the hygienist is carrying the handheld unit for some part of this extended period which contributes to fatigue, which can further hinder her ability to use the good technique required to get good images.

5. Compromised Safety

Distance is one of the most effective protections against radiation. For the operators that are using the equipment day in and day out, they are the ones who are most at risk of long term exposure. All things being equal, the effective dosage when you are one foot away from a radiation source is 100 times the effective dosage as when you are 10 feet away from that same source (for the math geeks following at home: it is an inverse square relationship).

6. Durability

Investing on a good quality mounted X-ray unit will definitely serve a lifespan of 8-12 years. This would work out to be a great return on investment in the long run, if the X-ray unit is made by a trusted manufacturer complying to international standards. It is still questionable whether buying a handheld X-ray unit would withstand the test of time.

7. Pliable Regulation

Regulations on handheld X-rays vary. Because of the concerns that the regulating bodies have with safety of handheld X-ray units, they are monitoring these products very closely. As a result, each state approaches them differently, and many of them create unique rules for different manufacturers. These regulations can vary from requiring additional protective aprons and gloves for the operator, to requiring that the office institute a radiation monitoring program. Some models may even be illegal. An FDA approved X-ray unit however, is considered to be a Gold Standard.

So what’s the solution?

For many offices, there is another option that provides the same, if not better cost advantage as the handheld, while at the same time avoiding the concerns mentioned above. This is the Mobile (Floor Mount) Intraskan DC Intraoral X-ray.

Skanray Intraskan DC X Ray Unit

The Intraskan DC Intraoral X-ray Unit provides:
• The ability to move the unit between operatories and avoid the cost of additional X-ray units in every room
• High power output (5 mA) that assures high quality images even if technique is less than perfect
• Motionless positioning that is supported by the unit, not the operator
• A convenient industrial-strength power cord which plugs into any standard wall outlet. Perfect for moving between operatories
• A robust, life-cycle tested design that assures positioning is rock-solid for years of operation
• No need for operator to carry around equipment, which reduces staff fatigue
• A trigger switch that allows the operator to leave the room during the X-ray
• A patented design to eliminate radiation leakage, which further enhances operator safety
• A compact footprint with high-performance wheels enabling smooth and agile maneuvering through the office
• A lower cost than many handheld X-rays

There’s an exciting offer on the FDA approved X-ray unit, Skanray Intraskan DC, at PinkBlue. Click here to know more about Skanray Intraskan DC, or mail us at support@pinkblue.in